Tuesday, February 1, 2022

A Typical Energy Analysis for a Commercial Customer


Many of our Customers Probably have no clue what a Energy Analysis is (As seen below)! It is a very useful tool, used for finding a film that will solve energy problems on any sized building. It will also tell you helpful information about your Rate of return on your investment in the Film! 

Many of the figures can be adjusted to create a custom analysis for your building! These are tools that experts at Made In The Shade Inc use to help you! Remember that energy savings are not the only way Films can save you money! How much is your favorite piece of art or furniture worth? What is you and your families comfort worth?
 
Maybe you live in a high crime area or a hurricane area; What is your Safety worth?

Call Made In The Shade Inc., Where YOU Are The COOLEST!, today to start saving your money, Your Skin (many Film's from many Manufactures carry the Skin Cancer Seal of Approval!) and Your possession's from the solar energy bombarding you and your building!

 
Call locally 480-985-9293 
Out of the Valley 1-888-577-TINT (8468) 
Log onto our extensive website:

amadeintheshade.com
Our email is: 
madeintheshadeinc@msn.com


Below is an example of a Energy Analysis!

13 October 2006
Manager
Neiman Marcus
6900 East Camelback Road
Scottsdale, AZ 85251
Dear Mr.
The attached economic analysis report was completed using Demand Analyzer, an energy simulation software package developed by ITEM Systems. As demonstrated within the report, the application of energy conservation products to your building may result in significant energy cost savings. For the products considered, the projected annual savings is $2,691 and the minimum payback period is 5.13 years.
Demand Analyzer utilizes the U.S. Department of Energy's sophisticated DOE-2 building energy analysis software for estimating energy savings for building projects. DOE-2 is a whole-building analysis program that calculates energy use and operating cost for each hour of the year, using typical weather data for the selected location. DOE-2 is widely used by consulting engineers for the design of energy-efficient buildings; by researchers for impact analysis of new heating, cooling and lighting technologies; and by state and federal agencies for developing energy-efficiency standards. DOE-2 is internationally recognized for the accuracy of its energy analysis algorithms as well as its ability to model a variety of buildings, HVAC systems and energy conservation measures. Additional information about ITEM Systems and Demand Analyzer is available at http://www.item.com and DOE-2 information can be found at http://gundog.lbl.gov.
The attached report summarizes the input data used to model your building and the resulting energy and cost savings for the selected Window Film products. You can be confident that your choice in installing these Window Films for your building is the right decision. Trusted and respected all over the world, these manufactures offer the best products to help you save money and assist in maintaining a comfortable building environment.
Thank you for your consideration of MITS Inc Film products.
Sincerely,
David E Ewing
President / CEO
Made In The Shade Inc.
Economic Analysis Summary

Annual Energy Cost ($)Annual Energy Cost Savings ($)Installed Cost ($)Simple Payback (Years)
Neiman Marcus Store Scottsdale 177,728 ------- ------- -------
Neiman Marcus Store Scottsdale w/V55 175,037 2,691 24,838 9.23
Neiman Marcus Store Scottsdale w/DR45 175,745 1,983 10,180 5.13
Neiman Marcus Store Scottsdale w/DG55 175,833 1,895 10,180 5.37
The energy savings shown are based on methods using the U.S. Department of Energy's DOE-2 energy simulation program. The methods used are believed to be reliable, but the accuracy and completeness thereof is not and cannot be guaranteed. Neither the party presenting this report, AIMCAL, the referenced film manufacturer, or the film seller assumes liability in connection with the inability to realize the estimated energy savings shown.
Building Parameter Summary
Neiman Marcus Store ScottsdaleNeiman Marcus Store Scottsdale w/VK 55Neiman Marcus Store Scottsdale w/DR-45Neiman Marcus Store Scottsdale w/DG 55
Building TypeLarge Retail Large Retail Large Retail Large Retail
Vintage1978-1992 1978-1992 1978-1992 1978-1992
CategoryNeimen Marcus Neimen Marcus Neimen Marcus Neimen Marcus
Climate ZoneAZ Phoenix AZ Phoenix AZ Phoenix AZ Phoenix
Utility Ratesdefault default default default
Floor Area (ft2)120000 120000 120000 120000
Aspect Ratio (E-W width / N-S width)1.0 1.0 1.01.0
Building Azimuth (degrees)0.0 0.0 0.0 0.0
Electricity: Energy Cost per kWh0.1 0.1 0.1 0.1
Electricity: Demand Cost per kW0.0 0.0 0.0 0.0
Electricity: Minimum Demand Cost per kW0.0 0.0 0.0 0.0
Electricity: Fixed Cost per Month0.0 0.0 0.0 0.0
Electricity: Minimum Cost per Month0.0 0.0 0.0 0.0
Electricity: Maximum Effective Rate per kWh0.0 0.0 0.0 0.0
Natural Gas: Energy Cost per therm0.5 0.5 0.5 0.5
Natural Gas: Fixed Cost per Month0.0 0.0 0.0 0.0
Natural Gas: Minimum Cost per Month0.0 0.0 0.0 0.0
Natural Gas: Maximum Effective Rate per therm0.0 0.0 0.0 0.0
Occupant Density (ft2/person): Showroom77.0 77.0 77.0 77.0
Occupant Density (ft2/person): Storage300.0 300.0 300.0 300.0
Occupant Density (ft2/person): Office150.0 150.0 150.0 150.0
Indoor Occupancy SensorsNo No No No
Indoor Lighting (W/ft2): Showroom1.0 1.0 1.0 1.0
Indoor Lighting (W/ft2): Storage1.0 1.0 1.0 1.0
Indoor Lighting (W/ft2): Office1.0 1.0 1.0 1.0
Outdoor Lighting: TypeMercury Vapor Lamps Mercury Vapor Lamps Mercury Vapor Lamps Mercury Vapor Lamps
Electrical Equipment (W/ft2): Showroom0.49 0.49 0.49 0.49
Electrical Equipment (W/ft2): Storage0.14 0.14 0.14 0.14
Electrical Equipment (W/ft2): Office0.69 0.69 0.69 0.69
Thermostat Setting (F): Heating, Setback60.0 60.0 60.0 60.0
Thermostat Setting (F): Cooling, Setback85.0 85.0 85.0 85.0
Thermostat Setting (F): Heating, Showroom, Office68.0 68.0 68.0 68.0
Thermostat Setting (F): Cooling, Showroom, Office77.0 77.0 77.0 77.0
Thermostat Setting (F): Heating, Storage65.0 65.0 65.0 65.0
Thermostat Setting (F): Cooling, Storage85.0 85.0 85.0 85.0
Ceiling/Roof Insulation (R-val)11.0 11.0 11.0 11.0
Roof Absorptance0.8 0.8 0.8 0.8
Air Curtain EntranceNo No No No
Adjacent Shading: NorthNo No No No
Adjacent Shading: EastNo No No No
Adjacent Shading: SouthNo No No No
Adjacent Shading: WestNo No No No
Window Area (ft2): North0.0 0.0 0.0 0.0
Window Area (ft2): East2122.0 2122.0 2122.0 2122.0
Window Area (ft2): South423.0 423.0 423.0 423.0
Window Area (ft2): West0.0 0.0 0.0 0.0
Window Setback (ft): North0.0 0.0 0.0 0.0
Window Setback (ft): East0.0 0.0 0.0 0.0
Window Setback (ft): South0.0 0.0 0.0 0.0
Window Setback (ft): West0.0 0.0 0.0 0.0
Window Shading (SC): North0.8 0.8 0.8 0.8
Window Shading (SC): East0.8 0.8 0.8 0.8
Window Shading (SC): South0.8 0.8 0.8 0.8
Window Shading (SC): West0.8 0.8 0.8 0.8
Window Glass Type: North7000,1/4" Clear Glass 9214,VK 55 on 1/4" Clear Glass7870,DR 45 on 1/4" Clear Glass7200,DG55 on 1/4" Clear Glass
Window Glass Type: East7000,1/4" Clear Glass 9214,VK 55 on 1/4" Clear Glass7870,DR 45 on 1/4" Clear Glass7200,DG 55 on 1/4" Clear Glass
Window Glass Type: South7000,1/4" Clear Glass 9214,VK 55 on 1/4" Clear Glass7870,DR 45 on 1/4" Clear Glass7200,DG 55 on 1/4" Clear Glass
Window Glass Type: West7000,1/4" Clear Glass 9214,VK 55 on 1/4" Clear Glass7870,DR 45 on 1/4" Clear Glass7200,DG 55 on 1/4" Clear Glass
DHW Heater TypeGas Gas Gas Gas
DHW Heater Efficiency0.8 0.8 0.8 0.8
DHW Tank InsulationNo No No No
DHW Pipe InsulationNo No No No
DHW Circulation Pump TimeclockNo No No No
Air Handler TypeVariable Air Volume Variable Air Volume Variable Air Volume Variable Air Volume
Ventilation Rate (cfm per person)20.0 20.0 20.0 20.0
Oversized CoilsNo No No No
Duct InsulationNo No No No
Air Side EconomizerYes Yes Yes Yes
HVAC System ClocksYes Yes Yes Yes
Energy Management SystemNo No No No
Deadband ThermostatsYes Yes Yes Yes
Heating PlantGas Boilers Gas Boilers Gas Boilers Gas Boilers
Cooling PlantCentrifugal Chillers Centrifugal Chillers Centrifugal Chillers Centrifugal Chillers
Cooling TowerPropeller Fans Propeller Fans Propeller Fans Propeller Fans
Heating Plant Efficiency0.8 0.8 0.8 0.8
Cooling Plant Efficiency4.5 4.5 4.5 4.5
Hot Water ResetNo No No No
Chilled Water ResetNo No No No
VSD Hot Water PumpsNo No No No
VSD Chilled Water PumpsNo No No No
Flue Heat RetrieverNo No No No
Infrared Space HeatersNo No No No
Chiller Strainer CycleNo No No No
Chiller OptimizerNo No No No
Thermal Energy StorageNo No No No
Indirect Evaporative Pre-CoolingNo No No No

No comments: